    FUCHS PLANTOHYD S詳細說明 (瀏覽1896次)
    FUCHS PLANTOHYD S


    Print

    Environmentally Friendly HEES Hydraulic Fluids and Lubricating Oils Based on Synthetic Esters


    Environmentally Friendly HEES Hydraulic Fluids and Lubricating Oils Based on Synthetic Esters

    It has been recognized for a number of years now that the use of mineral oil-based lubricants poses certain environmental risks. Leakages, emissions and spillages when handling hydraulic fluids lead to direct pollution of the surroundings and thus the environment. This fact led FUCHS to develop rapidly biodegradable lubricants based on vegetable oils and synthetic esters.

    The PLANTOHYD S series of oils are based on synthetic esters. They represent an environmentally friendly alternative to mineral oil-based hydraulic oils and can be classified as HEES fluids according to ISO/CD 6743-4. 

    The advantages of PLANTOHYD S are: 

    • Rapidly biodegradable (greater 90 % within 14 days according to CEC-L-33-A-93) 
    • German Water Hazard Class WGK 0, i.e. generally not hazardous for water 
    • Non-toxic, physiologically harmless 
    • Free of heavy metals 
    • Good low-temperature characteristics 
    • Excellent resistance to ageing and oxidation 
    • Excellent viscosity-temperature behaviour because of their high natural VI 
    • Excellent anti-wear properties 
    • Extremely shear-stable
    • Rapid air release 
    • Minimal foaming 
    • Insoluble in water
    • Good demulsibility characteristics. Applicable at tank temperatures ranging from - 35 °C to + 90 °C

    PLANTOHYD S products are fully compatible with all materials usually found in hydraulic systems. The base fluids used in these products are non-toxic. The fluids are free of heavy metals and chlorinated compounds. 

    Application:

    PLANTOHYD S hydraulic oils can be used universally in all hydraulic and general lubricating systems. They are suitable for all mobile and stationary hydraulic systems. These products should always be used whenever there is a danger of soil or water pollution following a leak or spillage. The greatest potential for such occurrences are in the construction, water, agricultural and forestry industries. Approvals from a number of well-known manufacturers have been issued. The high viscosity index of PLANTOHYD S products give them multigrade characteristics. 

    We recommend that the miscibility and compatibility of these products with mineral oil-based hydraulic oils should be checked on a case-by-case basis. As stated in ISO/CD ECO, residual quantities of mineral oil should be kept to a minimum by flushing prior to refilling. Compatible internal finishes on tanks should be selected. Paint finishes which are not 2-part epoxy systems can display poor resistance to mineral oil as well as synthetic esters. In general, we recommend the use of stainless steel tanks. "Free" metals, e.g. tin from soldered joints or zinc from galvanized components should be avoided if possible. Filter systems should also be compatible with synthetic ester fluids.

    The powerful cleaning effect of these fluids can dislodge large amounts of dirt and contaminants and this can, in turn, shorten the life of filters. System filters should be cleaned or changed after about the first week of use with PLANTOHYD S. The ISO/CD ECO guidelines should also be observed. To maintain optimum reliability, any water which has collected in systems which have been shut-down for longer periods should be drained. Water or moisture problems can be reduced if filtering or drying equipment is fitted to tank breathers. According to ISO/CD ECO, water content during use should be kept below 0.1 %. For ISO VG 10 to 22 fluids elastomer compatibility tests should be performed. 

    Our application engineers will be glad to advise you on: 

    • Experiences with these products 
    • Application possibilities 40 Material compatibility 
    • Change-over procedures
    and service facilities regarding PLANTO products.


    Typical data: 

    PLANTOHYD   10 S 15 S 22 S 32 S 46 S 68 S  
    Hydraulic oil type acc. to ISO/CD 6743-4 and VDMA 24 568   HEES 10 HEES 15 HEES 22 HEES 32 HEES 46 HEES 68  
    Characteristics Unit             Test method
    Colour   3 3.5 4 1 0.5 1 ASTM D 1500
    Kinematic viscosity                
    at 40 °C mm2/s 8.5 15.5 22.7 32.4 47.4 69 ASTM D 445
    at 100 °C mm2/s 2.5 4 5.4 7.1 49.3 13 ASTM D 445
    Viscosity index   125 162 191 188 184 191 ASTM D 2270
    Density at 15 °C kg/l 0.93 0.926 0.926 0.921 0.921 0.923 ASTM D 1298
    Flash point, Cleveland open cup °C 198 270 167 246 290 304 ASTM D 92
    Pour point °C < – 65 – 51 – 36 – 39 – 42 – 39 ASTM D 97
    Neutralization number mg KOH/g 0.8 1.2 1.3 1.2 1.2 1.8 ASTM D 974
    Copper corrosion degree of corr. 1a-100A3 1a-100A3 1a-100A3 1a-100A3 1a-100A3 1a-100A3 ASTM D 130
    Rust prevention   pass A pass A pass A pass A pass A pass A ASTM D 665
    Ageing behaviour at 110 °C, increase in viscosity at 40 °C after 72 h % < 20 < 20 < 20 < 20 < 20 < 20 DIN 51 554-3 (modified)
    FZG mechanical gear rig test load stage > 12 > 12 > 12 > 12 > 12 > 12 DIN 51 354-2


     Disclaimer of Liability
    上一產(chǎn)品: CASTROL Hyspin ZH-M
    下一產(chǎn)品: FUCHS RENOLIN B HVI液壓油
    Copyright (C) 2010 深圳市旺鴻達潤滑油貿(mào)易有限公司 b363838.com All Right Reserved
    地址:深圳市寶安區(qū)龍華街道龍觀東路金龍華廣場二期金龍閣1307室 電話:0755-29675629 傳真:0755-81472607 聯(lián)系人:歐陽民
    網(wǎng)址:b363838.com E-mail:shell2123@126.com 友情鏈接:旺鴻達潤滑油 粵ICP備16127079號
    1. <center id="pm6mu"></center>
      <label id="pm6mu"><optgroup id="pm6mu"></optgroup></label>
        <rt id="pm6mu"></rt>